Taman Mutiara Kavling #08, Pagutan
Mataram - West Lombok 83116
West Nusa Tenggara
Indonesia
Phone +62370636318 Ext.#49617
Mobile +628175799313
Fax +62370636318 Ext.#47694
E-mail Supriadi.3633@newmont.com
Supriadi
| Personal Information | Male Bandung, 24 January 1976 Indonesian Married |
| Experiences | 01 June 2004 - Present PT. Newmont Nusa Tenggara West Nusa Tenggara, ID Foreman Control & Instrumentation
13 Jan’2000-31 May’2004 PT. Newmont Nusa Tenggara West Nusa Tenggara, ID Leading Hand Electrical & Instrumentation
16 Oct’1995 - 3 Jan’2000 PT. BHP Steel Indonesia West Java, ID Electrical & Instrumentation Fitter
|
| Summary of qualification | 1. Process Control - DCS ABB Bailey basic handling - PLC’s Allen Bradley & Siemens SLC 5 basic Handling including trouble shooting - SAC field Controllers handling - Process Variables Tuned and Diagnostic of DCS Data Historian - Programmable Logic Control GEM80-400 (CEGELEC), is a Multi function logic controller which could be programmed and monitored by personal computer with Gemesys program for Windows and use GEM*) multi Processor system has two or more processor modules sharing the same central highway and read/write memory modules, that's why BHP Steel Indonesia using it to controlling the lines not just a part of section - Other PLC that’s used by independent machine as welding machine (Inductoheat), Water Cooling tower and Waste Water Treatment plant using Allen Bradley - PLC, Boiler using Omron PLC, and Air Compressor and Dryer use a Telemecanique. 2. Instrumentation - Radiation Sources Officer, Maintenance, trouble shooting and Calibration Radioisotope sources Instrumentation - Modification and Installing of the New Instrumentations at the Processing plant - Setting and Check all Instruments Parameters - Calibration all of Transmitter and Gauges - Weight scale, Density Gauges, Particle size analyze, On Stream Analyzer (AMDEL) and all Instrumentation Handling - Upgrade field Instrumentation devices performance for High Recovery product. - Data Measurement corporation (DMC) is a Weight gauge instrument that using feedback signal from Radioisotope source, 1 Ci Americium 241 (Beryllium Window) maintenance and calibration - H2, O2 gas and Dew point analyzer maintenance, check parameter and Calibration - pH and Conductivity analyzer maintenance, set parameter and Calibration - Branding machine Imaje S4 operating, set parameter and Calibration 3. Electrical - Synchronous and Gearless Motor of Mills trouble shooting and maintenance - 11 kV Switch Gear, Feeder 3.3 kV, 380 V MCC fault finding and maintenance - Transformers, Motors & Devices Interlock Maintenance - Alternative Current & Harmony Drives trouble shooting - Motor Control Center (MCC) is cubicles that used to wiring, panels and controllers centralization for controlling motor AC/DC and PLC also. - Direct Current (DC) drives GEMDRIVE is a directional current motor driver which controlling and protects motor to processing by references, feedback, and setting interlocks. - Switch Gear (Merlin Gerin) and Transformer (ABB) high voltage (20 kV / 380 V) Operating and Maintenance. - Generator (Aux. Power) DALE, Operating and Maintenance which only used to back up when Power blackout is happened for Inductors pot and Essentials Loads. 4. Combustion - Direct Fired Furnace (DFF) HNX fuel, maintenance and trouble Shooting - Boiler LPG fuel pilot and Oil fuel in normal firing condition, trouble shooting - Pre melt & Main Pot Inductors are molten metal pot which is Heating Circulating Produced by induction system of inductor coil , maintenance & troubleshooting - Oven, Incinerator and Lower Firing Level (LFL) are Natural Gas Burner Maintenance and trouble shooting. |
| Training | 22 – 23 August 2005 BATAN (National Nuclear Energy) Sumbawa, Indonesia Basic Radiation Safety (Certified)
18 – 22 May 2004 GE (General Electric) Sumbawa, Indonesia Multilin Protective Relay (Certified)
01 – 20 Oct’ 2001 BATAN (National Nuclear Energy) Jakarta, Indonesia RSO / Radiation Safety Officer (Certified)
10 Nov’–18 Dec’ 2000 UNIBRAW (Brawijaya University) Malang-East Java, Indonesia Instrumentation (Certified)
10 - 14 April 2000 CCSI (Completion & Commissioning Service Ind.) Sumbawa, Indonesia PID Process Control (Certified)
16 – 27 July 1997 Krakatau Training Center West Java, Indonesia Electrical Trouble shooting (Certified)
01 Nov – 10 Dec’1994 PT. PINDAD (Persero) West Java, Indonesia Electrical Practice Study (Certified)
1995 - 2007 PT. BHPSI and PT NNT Indonesia Other subjective Training and Course
|
| Education | 1992 - 1995 Technical High School 2 Bandung Bandung - West Java, Indonesia Industries Electrical (Certified)
1989 - 1992 Secondary School of Baleendah Bandung - West Java, Indonesia Secondary School (Certified) 1983 - 1989 Elementary School of Leuwi Bandung West Java, Indonesia Elementary School (Certified) |
| Professional memberships | RSO (Radiation Safety Officer) / Petugas Proteksi Radiasi of BATAN (Badan Tenaga Atom Nasional) Indonesia Frontline Operational Supervisor Certified (DEMR – Department Energy and Mineral Resources) / Sertifikasi Pengawas Operational K3LP (Direktur Teknik Dan Lingkungan Mineral, Batubara dan Panas Bumi). |
| Languages | Indonesian and English |
| References | Singgih Subiyantoro (General Foreman Process Electrical Maintenance) Singgih.Subiyantoro@newmont.com +628175749684 Brad Dunstan (Coordinator Electrical, Control and Instrumentation) Brad.Dunstan@newmont.com +628175749214 Stanley Jackson (Client Representative 3rd SAG Installation) Stan.Jackson@newmont.com +628175749262 |
| Objective | Electrical, Control and Instrumentation |
| Interests and activities | Running, Foot Ball and Computers |
| Awards received | GMP (Gold Medal Performance) achievements of PT. Newmont Nusa Tenggara program for some Modification and Initiative action to made Safer, Productive and Effective maintaining of Process equipment plant
|